Measuring range :0 to 45 000 kg/h (0 to 1654 lb/min)
Max. process pressure :PN 40
Measured variables :Mass flow, density, temperature, volume flow
Ambient temperature range :–20 to +60 °C (–4 to +140 °F)
Medium temperature range :–40 to +130 °C (–40 to +266 °F)150 °C allowed for 1 h
Brand Name :Endress+Hauser
Model Number :Dosimass Coriolis
Certification :CE
Place of Origin :Switzerland
MOQ :1PCS
Payment Terms :L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability :1000 Piece/Pieces per Week negotiable
Delivery Time :5-8 work days
Packaging Details :each unit has individual box and all boxes are packed in standard packages or customers requests available
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description
Dosimass Coriolis Flowmeter
The compact sensor with an ultra-compact transmitter for measurement of liquids with diverse properties in continuous process control & batching applications.
Field of Application
Dosimass is designed for filling and bottling applications in Food & Beverage and Life Sciences. In space-constrained applications, Dosimass is the preferred choice for system integrators, skid builders and equipment manufacturers. The flowmeter measures volume and mass flow directly with temperature and density compensation to ensure maximum repeatability, independent of physical fluid properties such as viscosity or density.
Key Benefits
  • High and stable filling performance with exceptional measuring accuracy and repeatability in shortest filling times
  • IO-Link enables real-time digital communication for easier commissioning and continuous data availability
  • Fewer process measuring points through multivariable measurement (flow, density, temperature)
  • Compact design for optimized machine footprint
  • Integrated batching functionality for comprehensive filling process management
  • Global compliance with industry standards: EHEDG, 3-A, FCM, cGMP
  • SIP and CIP cleanable
Technical Specifications
Measuring Principle
Coriolis
Measured Variables
Mass flow, density, temperature, volume flow
Max. Measurement Error
Mass flow (liquid): ±0.15%
Density (liquid): ±0.0005 g/cm³
Measuring Range
0 to 45,000 kg/h (0 to 1,654 lb/min)
Medium Temperature
-40 to +130 °C (-40 to +266 °F)
150 °C allowed for 1 hour
Max. Process Pressure
PN 40
Ambient Temperature
-20 to +60 °C (-4 to +140 °F)
Nominal Diameter
DN 1 to 40 (¹⁄₂₄ to 1¹⁄₂)
Degree of Protection
IP67, type 4X enclosure
Materials & Construction
Component Material Specifications
Measuring Tube 1.4435 (316/316L) - DN 1 to 4 mm (¹⁄₂₄ to ¹⁄₈)
1.4539 (904L) - DN 8 to 40 mm (³⁄₈ to 1½)
Process Connection 1.4435 (316/316L) - DN 1 to 4 mm (¹⁄₂₄ to ¹⁄₈)
1.4539 (904L) - DN 8 to 40 mm (³⁄₈ to 1½)
Sensor Housing Stainless steel, 1.4404 (316/316L) - DN 1 to 4 mm (¹⁄₂₄ to ¹⁄₈)
Stainless steel, 1.4301 (304) - DN 8 to 40 mm (³⁄₈ to 1½)
Transmitter Housing Stainless steel, 1.4409 (CF3M)
Electronics & Communication
Outputs
Pulse/frequency/switch output (passive)
Inputs
None
Digital Communication
Modbus RS485, IO-Link
Power Supply
DC 20 to 30 V
Display/Operation
No local operation
Configuration via operating tools possible
Certifications & Approvals
Hazardous Area: ATEX, UL, UK Ex
Other Approvals: 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, 3-A
Product Safety: CE