Industrial Site Production Explosion Proof Gas Analyzer KGD-MQ-509 Optimal Flow Rate 0.7-1.2L/min Water-free Gas Requirements

Contact Now
Xi'an Kacise Optronics Co.,Ltd.
Visit Website
Province/State:Shaanxi
Country/Region:china
Contact Person:MsEvelyn Wang
Contact Now

Industrial Site Production Explosion Proof Gas Analyzer KGD-MQ-509 Optimal Flow Rate 0.7-1.2L/min Water-free Gas Requirements

Ask Latest Price
Video Channel
Brand Name :KACISE
Model Number :KGD-MQ-509
Certification :CE
Place of Origin :CHINA
MOQ :1PCS
Payment Terms :L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability :1000 Piece/Pieces per Week negotiable
Delivery Time :5-8 work days
Packaging Details :each unit has individual box and all boxes are packed in standard packages or customers requests available
Measurement Principle :Tunable Diode Laser Absorption Spectroscopy (TDLAS)
Response Time ③ :<40s
Optimal Flow Rate ④ :0.7 - 1.2L/min
Gas Requirements :Dust - free, water - free, oil - free
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Explosion - proof Laser Gas Analyzer KGD - MQ - 509 for Industrial Site Production

Product Introduction

The Explosion - proof Laser Gas Analyzer KGD - MQ - 509 adopts Tunable Diode Laser Absorption Spectroscopy (TDLAS) technology and can simultaneously measure the volume concentrations of gases such as O₂, CO, CO₂, H₂S, and CH₄ on - line. The instrument is equipped with pre - treatment components and is suitable for harsh working conditions such as those with moisture and dust. Its explosion - proof design can meet the gas monitoring needs of flammable and explosive places in multiple fields, ensuring the safety of the production process in industrial sites.

Industrial Site Production Explosion Proof Gas Analyzer KGD-MQ-509 Optimal Flow Rate 0.7-1.2L/min Water-free Gas Requirements

Product Features

  • Adopts TDLAS technology with strong anti - interference ability.
  • Has a self - diagnosis function, enabling on - line inspection of sensor status.
  • High degree of automation, low maintenance requirements, and no need for manual on - site operation.
  • Multiple interfaces for data transmission, facilitating simple data management.
  • Explosion - proof grade: Ex d ⅡC T6

Technical Parameters

Measured Gas ① Range Accuracy ② Resolution
O₂ 0 - 10000ppm ±2%F.S. 1ppm
O₂ 0 - 5%VOL ±2%F.S. 0.01%
O₂ 0 - 25%VOL ±1%F.S. 0.01%
O₂ 0 - 100%VOL ±0.5%F.S. 0.01%
CO 0 - 500ppm ±2%F.S. 0.1ppm
CO 0 - 1000ppm ±1%F.S. 0.1ppm
CO 0 - 5%VOL ±2%F.S. 0.01%
CO 0 - 25%VOL ±1%F.S. 0.01%
CO 0 - 100%VOL ±1%F.S. 0.01%
CO₂ 0 - 1000ppm ±2%F.S. 0.1ppm
CO₂ 0 - 5%VOL ±2%F.S. 0.01%
CO₂ 0 - 25%VOL ±1%F.S. 0.01%
CO₂ 0 - 100%VOL ±1%F.S. 0.01%
H₂S 0 - 1000ppm ±2%F.S. 0.1ppm
H₂S 0 - 1%VOL ±2%F.S. 0.01%
CH₄ 0 - 100ppm ±2%F.S. 0.1ppm
CH₄ 0 - 1000ppm ±1%F.S. 0.1ppm
CH₄ 0 - 5%VOL ±1%F.S. 0.01%
CH₄ 0 - 25%VOL ±1%F.S. 0.01%
CH₄ 0 - 100%VOL ±1%F.S. 0.01%
Measurement Principle Tunable Diode Laser Absorption Spectroscopy (TDLAS)
Response Time ③ <40s
Optimal Flow Rate ④ 0.7 - 1.2L/min
Gas Requirements Dust - free, water - free, oil - free
Electrical Parameters
Communication RS - 485/RS - 232; 4 - 20mA
Power Supply AC220V, 50Hz
Display LCD Display
Explosion - proof Grade Ex d ⅡC T6
Functional Configuration Built - in zero - adjustment air pump for automatic air zero - adjustment; self - diagnosis function available for on - line inspection of sensor status
Notes:
① All data in the table are measured under standard atmospheric pressure.
② The standard gas for measurement is provided by a unit certified by the national metrology department. All gases are diluted in dry nitrogen; the accuracy requirement for nitrogen is greater than 99.999%.
③ The reference response time is tested at a flow rate of 2L/min.
④ The optimal flow rate is 0.7 - 1.2L/min, and the actual application can reach up to 2L/min.