Battery Thermal Runaway Monitoring Sensor KGD-ATRS-208
Product Introduction
The KGD-ATRS-208 battery thermal runaway monitoring sensor can effectively monitor the indicators of the concentrations of CO₂, CO, particulate matter and pressure released before the triggering of battery thermal runaway, and transmit the measurement signals to the BMS through CAN or LIN communication (customizable). It has remarkable features such as accurate measurement, fast response time, low cross-interference, low power consumption, long service life, and high reliability.
Product Features
Technical Parameters
Measurement Principle | NDIR dual-channel + MOX + light scattering |
Measurement Components | PM2.5 + CO₂ + CO + P |
Communication Method | CAN |
Communication Parameters | 500k |
Measurement Range | CO₂: 0~10000ppm; CO: 0~1000ppm (can display up to 10000ppm); PM: 0~5mg/m³; Air pressure P: 80kPa~120kPa |
Response Time | T90 ≤ 15s |
Measurement Precision | CO₂: ±200ppm or ±20% of the reading @0~5000ppm & -20°C~60°C; CO: take the larger value between ±40ppm or ±30% of the reading; PM: ≤100ug/m³: ±15ug/m³; >100ug/m³: ±15% of the reading @-40℃~70℃; Pressure P: ±1kPa |
Resolution | CO₂/CO: 1ppm; PM: 1μg/m³; Air pressure P: 0.1kPa |