KIFFM E Flow Injection Chemiluminescence Analyzer Wavelength Range 300-650 nm Input High Voltage -100 to -1000 V for Results

Ask Latest Price
Video Channel
Brand Name :KACISE
Model Number :KIFFM - E
Certification :CE
Place of Origin :CHINA
MOQ :1PCS
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :1000 Piece/Pieces per Week negotiable
Delivery Time :5-8 work days
Packaging Details :each unit has individual box and all boxes are packed in standard packages or customers requests available
Gain control :1X, 2X, 4X, 8X, 16X
Filter cut - off frequency adjustment :10 - 100 Hz
Sampling rate :1 - 100T/S
Input high voltage :- 100 to - 1000 V,
stability :better than 0.01%
Wavelength range :300 - 650 nm (maximum response wavelength: 420 nm)
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Technical Parameters of KIFFM - E Flow Injection Chemiluminescence Analyzer

Product Introduction

The KIFFM - E flow injection chemiluminescence analyzer is the earliest fully - automatic chemiluminescence detection and analysis system launched in China. The instrument integrates a high - precision dual - peristaltic pump numerically - controlled wide - speed - regulation flow injection sampling system, an IFFS - A multi - functional ultra - weak chemiluminescence detector, and chemical spectrogram analysis software, and can perform analyses such as static injection chemiluminescence analysis and flow injection chemiluminescence.

Application Fields

  • Research on static and flow injection photometric analysis
  • Flow injection on - line testing and analysis

Technical Features

  • High - precision Peristaltic Pump Wide - range Digital Speed - regulation System
  • High - precision peristaltic pump wide - range digital speed - regulation system: Speed - regulation range 0 - 99 levels
  • Forward/reverse function can realize oscillation, mixing, separation, and extraction of solutions in pipelines
  • Pump - stop function can be used for slow - reaction analysis or for micro - sampling
  • Or achieve up to 10 - channel pipeline injection (5 channels/pump)
  • Can realize automatic dilution of solutions, with a maximum dilution ratio of 1:99
  • 16 - channel automatic/manual valve
  • Analysts can arbitrarily adjust the speed, running time, running direction, number of cycles, cycle starting point, positions of two injection valves, reading output, and termination step of the peristaltic pump
  • IFFS - A Multi - functional Chemiluminescence Detector
  • It can perform various luminescence detections such as static injection chemiluminescence, capillary electrophoresis chemiluminescence, and capillary electrophoresis electrochemiluminescence, and can also be used as a shield for electrochemical detection to shield the influence of external electromagnetic interference signals.

Technical Specifications

Input high voltage: - 100 to - 1000 V, stability: better than 0.01%

Wavelength range: 300 - 650 nm (maximum response wavelength: 420 nm)

SP > 1000 A/Lm, programmable high - precision negative high - voltage power supply and high - precision pre - amplifier, record analog signal output

High - precision Data Acquisition System, Controlled by Computer, Capable of

Gain control: 1X, 2X, 4X, 8X, 16X

Filter cut - off frequency adjustment: 10 - 100 Hz

Sampling rate: 1 - 100T/S

Automatic/manual zero - setting

External signal input interface, which can receive analog signals from other instruments, input range: 0 - 5V

REMEX Fully Chinese - Language Data Analysis System

The measurement system can complete the setting and control of sampler parameters, the setting and control of analysis parameters, real - time data acquisition of chemical reaction kinetics, and curve plotting. In the repeated measurement state, it can perform kinetic curve tests such as cumulative superposition and average superposition synchronously with the sampling system.

Measurement and processing of measured spectrogram data: The value at any point of the measured spectrogram can be read. The effective area can be set for the waveforms at any two points of the measured spectrogram, and the area, peak value, valley value, and average value can be calculated. Abnormal points in the measured spectrogram can be removed one by one or in multiple points.