Xi'an Kacise Optronics Co.,Ltd.

Kacise, understanding your automation needs.

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Gas Detector Sensor /

KAN101 Point - Type Combustible Gas Detector For Industrial And Commercial Applications

Contact Now
Xi'an Kacise Optronics Co.,Ltd.
Visit Website
Province/State:Shaanxi
Country/Region:china
Contact Person:MsEvelyn Wang
Contact Now

KAN101 Point - Type Combustible Gas Detector For Industrial And Commercial Applications

Ask Latest Price
Video Channel
Brand Name :KACISE
Model Number :KAN101
Certification :CE
Place of Origin :CHINA
MOQ :1PCS
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :1000 Piece/Pieces per Week negotiable
Delivery Time :5-8 work days
Packaging Details :each unit has individual box and all boxes are packed in standard packages or customers requests available
Detection Principle and Gas :Catalytic combustion type: Methane, Propane, Isobutane, Hydrogen
Detection Range and Sampling Method :Diffusion type: 3 - 100% LEL
Communication Distance :≤ 1000m (RVSP1.5mm²)
Communication Method :ABUS four - wire bus
Specification :Cast aluminum ≤ 1.2Kg, 206×165×80
Explosion - proof Mark and Protection Level :Ex db II CT6 Gb IP66
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

KAN101 Point - type Combustible Gas Detector for Industrial and Commercial Applications

Product Introduction

The power supply and bus are designed in a non - polar way, which is convenient for wiring and highly reliable. This product is designed with embedded technology and has the function of detecting linear attenuation compensation. It comes with an output interface for an audible and visual alarm and a passive output interface. The housing is cast with an alloy process, featuring low density, high strength, and strong corrosion resistance.

KAN101 Point - Type Combustible Gas Detector For Industrial And Commercial Applications

Product Description

Detection Principle and Gas Detection Range and Sampling Method Operating Voltage and Power Consumption Communication Distance
Catalytic combustion type: Methane, Propane, Isobutane, Hydrogen Diffusion type: 3 - 100% LEL DC24V ± 6V
Normal power consumption ≤ 1.5W (DC24V)
Alarm power consumption ≤ 3W (DC24V)
≤ 1000m (RVSP1.5mm²)
Electrical Interface Explosion - proof Mark and Protection Level Output Capacity Communication Method
G3/4" internal thread Ex db II CT6 Gb IP66 1 set of passive switch output: 220VAC/24VDC, 2A
1 set of active audible and visual alarm output
ABUS four - wire bus
Alarm Value Operating Temperature and Humidity Display Method Specification
25% LEL - 50% LEL (factory - set value) -40°C - +70°C, ≤ 93% RH Three - color (red, green, yellow) lights for working status display Cast aluminum ≤ 1.2Kg, 206×165×80

Inquiry Cart 0