Add to Cart
The KTG101 portable chromatographic analyzer is applied to the process analysis of natural gas
Introduction
The KTG101 series chromatographic analyzer adopts the advanced Etch process to make the gas circuit control more stable and has a low operation cost. It solves the disadvantages such as large volume, long analysis time, and high consumption. With a 7" true-color screen, it provides on-site indication and touch operation. The device has a system prediction and diagnosis function, and is simple to use, convenient to operate, and has complete functions. At present, it has been widely applied in the petroleum and natural gas field and has won the praise of a large number of users.
Product Applications
Product Features
Main Indicators
Repeatability: 0.01%
Accuracy: ≤0.1%FS
Calculated Values: Calorific value, density, compression factor, etc. (in line with ISO6976 or GPA standards, Z by AGA 8)
Operating Temperature: -20℃ to 50℃( -4℉ to 122℉)
Storage Temperature: -30℃ to 60℃(-22℉ to 140℉)
Overall Dimensions: 320×290×190mm (Length * Width * Height)
Weight: Approximately 32Kg
Analysis Performance
Analysis Time: Less than 60s for C6+
Pressure Control: With electronic carrier gas pressure control
Thermostatic Oven: Key components such as the chromatographic column, detector, and sampling loop are all placed in the thermostatic oven, which has a temperature overheating protection function.
The main unit of the chromatographic analyzer can display information such as gas components, compression factor, calorific value, and density on-site, and can select the display content and configure the display mode through touch. It has a powerful recording and storage function, with historical records of at least 12 months, including calibration records and data result records, etc.
Communication Functions
Communication Interfaces: 2 RS485, 2 RS232, and one RJ45
Analog Interfaces: 16 channels of 4~20mA (expandable)
Communication Protocols: Modbus RTU, TCP/IP protocols
Digital Interfaces: Up to 8 digital outputs, including comprehensive chromatographic alarms, automatic calibration control, etc.
Operation Interface
The on-site 7" true-color K600+65k-color DGUS large screen is used for display and touch operation. It can display each measured and calculated component and key chromatographic control parameters, and start functions such as automatic/manual parameter setting of the chromatograph.
Utility Engineering
Power Supply: 220VAC 50Hz Carrier Gas: He or H2 or N2 or Ar
Consumption: Less than 10ml/min Purity: 99.995% and above