The KSCY5 infrared ethylene oxide sensor is a gas sensor module that uses the NDIR infrared absorption detection principle. KSCY5 uses MEMS light source, special structure optical cavity and dual-channel detector to achieve spatial dual optical path reference compensation, and the microprocessor performs signal acquisition, processing and output. KSCY5 has good selectivity, high sensitivity, no oxygen dependence, long life and low power consumption; built-in temperature sensor for temperature compensation; also has UART, 485 output and analog current/voltage output; alarm points can be set to facilitate customers to use in different application scenarios.
Technical Parameters
Working conditions | |||||
Description | Symbol | Value | Unit | ||
Storage temperature | Tstg | -20 to 80 | °C | ||
Operating temperature | TA | -20 to 60 | °C | ||
Operating humidity | HA | 0 to 90 | % RH | ||
Operating pressure | PA | 0.8 to 1.2 | ATM | ||
Electrical characteristics | |||||
Description | Symbol | Min | Typical | Max | Unit |
Power supply | Vs | 9 | 12 | 15 | V |
Maximum operating current Heating | Imax | 490 | 510 | 515 | mA |
Maximum operating current Not heating | Imax | 110 | 120 | 140 | mA |
Performance parameters | |||||
Description | Min | Typical | Max | Unit | |
Detection range | 100 | 1000 | 100% | ppm | |
Measurement accuracy | 1 | 1 | 1 | ppm | |
T90 | Pump suction | 15 | ≤30 | ≤30 | s |
Repeatability | Zero point | <±50 | ppm | ||
50% FS | - | <±5% of measured value | - | ppm | |
life | 3 | 5 | 10 | Years |