Inertial Angular Rate Sensor Based On Optical Sagnac Effect Use In Measure Angular Velocity,start time 5(s)

Contact Now
Xi'an Kacise Optronics Co.,Ltd.
Visit Website
Province/State:Shaanxi
Country/Region:china
Contact Person:MsEvelyn Wang
Contact Now

Inertial Angular Rate Sensor Based On Optical Sagnac Effect Use In Measure Angular Velocity,start time 5(s)

Ask Latest Price
Video Channel
Brand Name :Kacise
Model Number :K1FOG20
Certification :certificate of explosion-proof, CE
Place of Origin :China (Mainland)
MOQ :1pcs
Payment Terms :T/T, Western Union, MoneyGram
Supply Ability :1000 Pieces per Week
Packaging Details :each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time :5-8 working days
Dimensions :50×50×36(mm)
start time :5(s)
Bias drift :≤0.1(°) / h (10s smooth, fix temperature)
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

K1FOG20 series Gyro

Product Description:

This product is an inertial angle rate sensor based on the optical Sagnac effect for measuring the rotational angular velocity of the carrier along the sensitive axis. The digital closed-loop detection circuit is used to extract the optical path difference of the clockwise light caused by the external physical angular speed, and the voltage signal of the optical path signal is modulated and demodulation, and the closed loop feedback and control are realized to achieve the purpose of real-time angular velocity signal detection.

Function: This product consists of two parts: optical angular velocity sensitive unit and signal detection, providing uniaxial angle increment information and internal temperature information.

Application scope: The products are mainly suitable for photoelectric crane / crane / flying platform / inertial navigation / inertial measurement system / optical / photographic instrument / platform stabilization device / inertial measurement instrument and other applications.

Inertial Angular Rate Sensor Based On Optical Sagnac Effect Use In Measure Angular Velocity,start time 5(s)Inertial Angular Rate Sensor Based On Optical Sagnac Effect Use In Measure Angular Velocity,start time 5(s)

Installation mode 1. Size: 50X50X32

Inertial Angular Rate Sensor Based On Optical Sagnac Effect Use In Measure Angular Velocity,start time 5(s)

Installation mode: 2nd dimension: 50X50X36

Main performance parameters

Sn# test item H L
1 Dimensions (mm) 50×50×36 50×50×36
2 start time (s) 5 5
3 Bias drift (°) / h (10s smooth, fix temperature) ≤0.1 ≤0.3
4 Bias drift (°) / h (10s smooth) -45~ + 70 ≤0.3 ≤0.5
5 Bias repeatability (°) / h ≤0.05 ≤0.1
6 Random walk coefficient(º)/h1/2 ≤0.01 ≤0.02
7 Scale factor non-linearity (ppm) ≤10 ≤20
8 Scale factor repeatability (ppm) ≤10 ≤20
9 Operate temperature ℃ -45~+70 -45~+70
10 Storage temperature of (℃) -50~+80 -50~+80
11 Dynamic range (°) / s ±900 ±900
12 Supply voltage (V) +5 +5
13 Steady-state power consumption (full temperature) (W) <4 <4
14 weight (g) <130 <130

Support and Services:

Electronic Gyroscope Sensor Technical Support and Service
  • Provide technical support for any product related questions
  • Provide assistance with installation and setup of the product
  • Provide troubleshooting support to resolve any technical issues
  • Provide software updates and patches to ensure the product is up to date
  • Provide assistance with warranty claims and repairs
  • Provide advice and guidance on best practices for using the product
  • Provide training and education on the product and its features

Packing and Shipping:

Packaging and Shipping of Electronic Gyroscope Sensor

All Electronic Gyroscope Sensors should be packaged and shipped in accordance with the following guidelines:

  • The Gyroscope Sensors should be packed in a sturdy box with enough cushioning material to protect it from any shock or vibration.
  • The box should be clearly labeled with the contents, destination, and sender information.
  • The box should be sealed with a tamper-evident seal, to ensure that the product has not been tampered with.
  • The box should be shipped via a reputable courier service, to ensure that it arrives in a timely manner and in good condition.

Company Information

Inertial Angular Rate Sensor Based On Optical Sagnac Effect Use In Measure Angular Velocity,start time 5(s)
Xi'an Kacise is certified by ISO 9001-2008, GJB 9001B-2009, CE, intrinsic safety explosion-proof and isolated safety explosion-proof, etc. which assure our products are conform to the international standards.
We have been specializing in manufacturing pressure, level and flow measuring instruments and related products for 10 years. We have experienced technical and management personnel, through the efforts of our entire staff, we have become a professional measuring instrument manufacturer and solution provider.
Currently, Kacise sensor is already exported to America, Spain, Australia, Chile and 20 other countries and regions, and received many favorable feedbacks. Our overseas distributers are also increasing.
We supply high quality Turbine Gas Flow Meter, hope we can coopperate in near future by providing you suitable products, good services and reasonable prices.

Inquiry Cart 0