Add to Cart
KLD800 Series FM CW 80GHz Non-contact Corrosion Resistant Lens Antenna Radar Level Transmitter For Liquid and Solid
Introduction
80GHz frequency modulation radar level transmitter is also called frequency modulation continuous wave (FMCW) radar level transmitter, which is a higher frequency radar level gauge. Its main advantages are smaller emission angle, more concentrated energy, stronger echo signal, stronger penetration, and higher measurement accuracy. It can be applied to various occasions and is more stable than other radar products.
It is effective in harsh conditions. Whether it is a toxic medium, or a corrosive medium, and whether it is a solid, liquid, dusty, or slurry medium, it can be measured.
Feature
1. More compact architecture, higher signal-to-noise ratio, and smaller blind spots.
2. Higher measurement resolution and measurement accuracy.
3. The narrowt 3° antenna beam angle, the interference in the installation environment will have less impact on the instrument, and the installation is more convenient.
4. The wavelength is shorter and has better reflection characteristics on solid surfaces, so there is no need to use special universal flanges for aiming.
5. Stable performance and long life. It can adapt to various environments and working conditions, and has strong corrosion resistance and anti-interference ability, and can work in various harsh working conditions.
6. Accurate, safe and energy-saving: The chemical and mechanical properties of the materials used in radar level gauges are quite stable, and the materials can be recycled, which is extremely environmentally friendly.
7. Maintenance-free and highly reliable: Microwaves are almost immune to interference and do not directly contact the measurement medium, so they can be used in almost all occasions, such as vacuum measurement, liquid level measurement or material level measurement, etc. Due to the use of advanced materials, it is durable to extremely complex chemical and physical conditions, and it can provide accurate, reliable, long-term stable analog or digital level signals.
KLD801 | Medium: liquid, non-corrosive |
Measuring range: 0.05m~10/20/30/60/100m | |
Process connection: G1½A / 1½NPT thread / flange ≥ DN40 | |
Process temperature: -40~80℃ | |
Process pressure: -0.1~0.3 MPa | |
Antenna size: 32mm lens antenna | |
Antenna material: PTFE | |
Accuracy: ±2mm | |
Protection class: IP67 | |
Center frequency: 80GHz | |
Launch angle: 3° | |
Power supply: Two-wire /DC24V | |
Four-wire system/DC12~24V | |
Four-wire system/AC220V | |
Casing: aluminum/plastic/stainless steel | |
Signal output: two-wire /4...20mA/HART protocol | |
Four-wire system: 4...20mA/ RS485 Modbus | |
KLD802 | Medium: non-corrosive liquid, slightly corrosive liquid |
Measuring range: 0.1m~10/20/30/60/100m | |
Process connection: flange ≥ DN80 | |
Process temperature: -40~110℃ | |
Process pressure: -0.1~1.6MPa | |
Antenna size: 32mm lens antenna | |
Antenna material: PTFE | |
Accuracy: ±2mm (range below 35m) | |
±5mm (range between 35m and 100m) | |
Protection class: IP67 | |
Center frequency: 80GHz | |
Launch angle: 3° | |
Power supply: two-wire /DC24V | |
four-wire /DC12~24V | |
four-wire /AC220V | |
Casing: aluminum/stainless steel | |
Signal output: two-wire /4...20mA/HART protocol | |
four-wire / 4...20mA/ RS485 Modbus | |
KLD803 | Medium: strong corrosive liquid, steam, foam |
Measuring range: 0.1m~10/20/30/60/100m | |
Process connection: flange ≥ DN50 | |
Process temperature: -40~130℃ | |
Process pressure: -0.1~2.5MPa | |
Antenna size: 34mm lens antenna (according to flange size) | |
Antenna material: PTFE | |
Accuracy: ±2mm (range below 35m) | |
±5mm (range between 35m and 100m) | |
Protection class: IP67 | |
Center frequency: 80GHz | |
Launch angle: 3° | |
Power supply: two-wire /DC24V | |
four-wire /DC12~24V | |
four-wire /AC220V | |
Casing: aluminum/stainless steel | |
Signal output: two-wire /4...20mA/HART protocol | |
four-wire 4...20mA/ RS485 Modbus | |
KLD804 | Medium: strong corrosive liquid, steam, foam |
Measuring range: 0.1m~10/20/30/60/100m | |
Process connection: flange ≥ DN50 | |
Process temperature: -40~130℃ | |
Process pressure: -0.1~1.0MPa | |
Antenna size: 76mm lens antenna | |
Antenna material: PTFE | |
Accuracy: ±2mm | |
Protection class: IP67 | |
Center frequency: 80GHz | |
Launch angle: 2° | |
Power supply: two-wire /DC24V | |
four-wire /DC12~24V | |
four-wire /AC220V | |
Casing: aluminum/plastic/stainless steel | |
Signal output: two-wire /4...20mA/HART protocol | |
four-wire 4...20mA/ RS485 Modbus | |
KLD805 | Medium: strong corrosive liquid, steam, foam, |
high temperature. and high pressure | |
Measuring range: 0.1m~10/20/30/60/100m | |
Process connection: flange ≥ DN80 | |
Process temperature: -40~200℃ | |
Process pressure: -0.1~2.5MPa | |
Antenna size: 76mm lens antenna (according to flange size) | |
Antenna material: PTFE/overall filling | |
Accuracy: ±2mm | |
Protection class: IP67 | |
Center frequency: 80GHz | |
Launch angle: 3° | |
Power supply: two-wire /DC24V | |
four-wire /DC12~24V | |
four-wire /AC220V | |
Casing: aluminum / plastic / stainless steel | |
Signal output: two-wire /4...20mA/HART protocol | |
four-wire 4...20mA/ RS485 Modbus | |
KLD806 | Medium: solid, storage container, process container, |
strong dust application | |
Measuring range: 0.3m~10/20/30/60/100m | |
Process connection: flange ≥ DN100 | |
Process temperature: -40~110℃ | |
Process pressure: -0.1~0.3MPa | |
Antenna size: 76mm lens antenna (purge optional) | |
Antenna material: PTFE | |
Accuracy: ±5mm | |
Protection class: IP67 | |
Center frequency: 80GHz | |
Launch angle: 3° | |
Power supply: two-wire /DC24V | |
four-wire /DC12~24V | |
four-wire /AC220V | |
Casing: aluminum/plastic/stainless steel | |
Signal output: two-wire /4...20mA/HART protocol | |
four-wire 4...20mA/ RS485 Modbus |
KWL800 water level sensor
Transmit Frequency | 76GHz~81GHz |
Measuring Range | 0.1 m ~ 65m |
Measurement Accuracy | ±1mm |
Beam Angle | 6° |
Power Supply Range | 9~36 VDC |
Communication Method | RS485 |
Operating Temperature | -40~85℃ |
Shell Material | PP |
Antenna Type | Lens antenna |
Recommended Cable | 7*0.3mm² |
Protection | IP68 |
Installation Method | Bracket |
Installation Method
Thread installation (KLD801)
Flange installation
When using flange installation, the minimum distance between the instrument and the tank
wall should be 200mm.
① datum plane
② vessel center or axis of symmetry
Hoisting Installation