Add to Cart
1. Parameter
Model: KUS600 | |
Measuring range | 600... 5000 mm. The measure distance can reach 6 meters if the power supply is 24V. |
Blind spot | 600 mm |
Supply voltage | 3.3 ... 24 VDC,ripple 10 %SS |
No-load supply current I0 | ≤ 20 mA active period and ≤0.3mA during sleep time |
Output signal | 0-10V. 0-3V 0-5V /4-20mA/NPN/PNP/RS485 Analog output. |
Measurement accuracy | ≤1 %F.S. |
Temperature compensation | Yes |
Ranging resolution | 0.1mm; |
Working conditions
Working temperature | -40…85℃(233...358K) |
Storage temperature | -40…85℃(233...358K) |
Other instructions
Electrical connection | 5-core cable (analog output), 6-core cable (switch output); |
Protection class | IP67 |
shell material | PVC /PVDF/PTFE/ABS |
Electrical connections and signal definitions
Line order | Colour | Definition |
1 | Red | Power is positive |
2 | Black | power return ground |
3 | Yellow | Analog output, voltage output, current output switch output |
4 | Blue | RS485 A+ or uart TXD |
5 | Green | RS485 B- or uart RXD |
Unit in the diagram is mm
4. Installation conditions
If the sensor is installed at the environment temperature fall below 0℃,It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.
5. Ordering information
KUS | model | output | range | describe |
630 | Product series model | |||
Custom made | ||||
0-10V | Analog 0-10V output | |||
0-5V | Analog 0-5V output | |||
0-3V | Analog 0-3V output | |||
4-20mA | Analog 4-20mA output | |||
SW | Switch output | |||
Uart | Uart serial output MODBUS RTU protocol | |||
RS485 | RS485 output MODBUS RTU protocol | |||
XX m | XX m means the maximum measurement distance (default 10m) | |||
KUS | 550 | RS485 | 2m |
6. Packing and shipping