Infrared CO2 Gas Sensor Module Carbon Dioxide Sensor Module

Ask Latest Price
Video Channel
Brand Name :Kacise
Model Number :KCS551
Place of Origin :shanxi xi'an
MOQ :1
Payment Terms :T/T, Western Union, MoneyGram
Supply Ability :1000 Pieces per Week
Delivery Time :5 work days
Packaging Details :each unit has indicidual box and all boxes are packed in standard packages or customers requests available
Storage Temperature :-20-80℃
Operating Temperature :-20-60℃
Operating Humidity :0-90%RH
Work Pressure :0.8-1.2 atm
Supply Voltage :12V
Maximum Operating Current :100-150mA
T90 :5S
Repeatability of Zero :<±50 ppm
Repeatability of 50% FS :<±5% of the measured value
Life Span :10 year
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

KCS551 Infrared CO2 Gas Sensor Module

1. overview

KCS551 is a gas detection module based on the principle of NDIR infrared absorption, which is suitable for detecting the concentration of carbon dioxide in a gaseous environment at room temperature.

KCS551 adopts a patented optical cavity, imported light source and dual-channel detector to realize the reference compensation of dual optical paths in space. KCS551 has good selectivity, no oxygen dependence and long life.

KCS551 has UART, IIC digital output, analog voltage output and PWM frequency output mode, which is convenient for customers to choose the application; The KCS551 provides zero point calibration, sensitivity calibration, and clean air calibration commands, and provides customers with a manually calibrated MCDL pin to facilitate the relative zero calibration of sensor modules using outdoor free-flowing clean air. KCS551 adopts diffusion ventilation method, which has a fast diffusion speed.

KCS551 can be widely used in HVAC fresh air control, indoor air quality monitoring, agricultural and animal husbandry production process monitoring, can be installed in intelligent buildings, ventilation systems, robots, automotive and other applications. It can also be applied to other confined spaces for air quality monitoring.

2. Technical parameters

parameter symbol minimum Typical values maximum unit
Storage Temperature Tstg -20 - 80 °C
Operating Temperature TA -20 60 °C
Operating Humidity HA 0 90 % RH
Work Pressure PA 0.8 1.2 atm
Supply Voltage Vs 11 12 30 V
Maximum Operating Current Imax 100 120 150 mA
T90 Pump suction - 5 second
Repeatability zero <±50 ppm
50% FS - <± 2% of the measured value -
Life Span 10 year

3.Structural dimension drawing

Unit: mm

Infrared CO2 Gas Sensor Module Carbon Dioxide Sensor Module

Diffusion

Infrared CO2 Gas Sensor Module Carbon Dioxide Sensor Module

Pump-suction type

4.Installation instructions

The sensor is mounted with a positioning hole spacing of 44.5mand a mounting hole diameter of 2.8 mm

The wiring socket spacing is 2.54 m m

Note: SW400PV3.01, mounting aperture: 3.2mm

5. Matters that should be paid attention to in maintenance

The sensor should be calibrated regularly, it is recommended that it be no more than 3 months, and calibration is not required on the long-term operation side if automatic calibration is turned on

Do not use the sensor for a long time in an environment with a high density of dust

Please use the sensor within the range of the sensor's power supply

6. Ordering instructions

In order to be able to purchase the specific specifications required, please provide the following information

1) Sensor name

2) Sensor range

3) Sensor measurement accuracy such as SW400, 0-2000pp

7. Order Information

Order information sheet
KCS551 KCS551 CO2 concentration sensor
xxxx The sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm.
2000 Range 200ppm (default).
10000 Range 10000ppm
50000 Range 50000ppm
encode The reaction speed is divided into two types: fast and slow
S Slow (default).
Q fast
encode Baud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering.
Custom Confirm the baud rate before ordering
2400 2400bps baud rate
9600 9600bps baud rate
19200 19200bps baud rate
38400 38400bps baud rate (default)
encode Serial port protocol
Modbus-RTU Standard Modbus-RTU protocol (default).
Modbus-ASCII Standard Modbus-ASCII protocol
Modbus-Self Modbus private protocol
KCS551 -2000 -S -38400 -Modbus-RTU

8. Contact Details

URL: www.kacise.com

Tel: +86-29-17719566736

Email: sales@kacise.com

Address: Tangyan South Road, Xi'an City, Shaanxi Province, China

Appendix

Shorthand Full name
VOL 1% VOL refers to 1% of the volume of a particular gas in air.
PPM 1PPM means that the volume of a specific gas in the air accounts for one millionth.
O2 Oxygen molecules
LCD LCD display
RS485 Asynchronous serial port 485
DC direct current
AC Communication
PVC polyvinyl chloride