Xi'an Kacise Optronics Co.,Ltd.

Kacise, understanding your automation needs.

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Gas Detector Sensor /

Ir Ndir Co2 Sensor Module 50000ppm Carbon Dioxide Sensor Module

Contact Now
Xi'an Kacise Optronics Co.,Ltd.
Visit Website
Province/State:Shaanxi
Country/Region:china
Contact Person:MsEvelyn Wang
Contact Now

Ir Ndir Co2 Sensor Module 50000ppm Carbon Dioxide Sensor Module

Ask Latest Price
Video Channel
Brand Name :Kacise
Model Number :KCS540
Place of Origin :shanxi xi'an
MOQ :1
Payment Terms :T/T, Western Union, MoneyGram
Supply Ability :1000 Pieces per Week
Delivery Time :5 work days
Packaging Details :each unit has indicidual box and all boxes are packed in standard packages or customers requests available
Storage temperature :-20-80℃
Operating temperature :-20-60℃
Operating humidity :0-90%RH
Work pressure :0.8-1.2atm
Supply voltage :12V
Maximum operating current :120-150mA
Detection range :50000ppm
Measurement accuracy :± 20ppm or ±5% true value ppm
T90 :30S
Repeatability of Zero :<±50 ppm
Repeatability of 50% FS :<± 2% of the measured value
Life Span :10 year
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

KCS540 Infrared CO2 Module

1. overview

KCS540 is a gas detection module based on the principle of NDIR infrared absorption, which is suitable for detecting the concentration of carbon dioxide in a gaseous environment at room temperature.

KCS540 adopts a patented optical cavity, imported light source and dual-channel detector to achieve dual optical path reference compensation in space. KCS540 has good selectivity, no oxygen dependence and long life.

KCS540 has UART, IEC digital output, analog voltage output and PWM frequency output mode, which is convenient for customers to choose the application; The KCS540 provides zero calibration, sensitivity calibration, and clean air calibration commands, and provides customers with a manually calibrated MCDL pin to facilitate the relative zero calibration of the sensor module using outdoor free-flowing clean air. KCS540 adopts diffusion ventilation method, which has a fast diffusion speed.

KCS540 can be widely used in HVAC fresh air control, indoor air quality monitoring, agricultural and animal husbandry production process monitoring, can be installed in intelligent buildings, ventilation systems, robots, automobiles and other applications. It can also be applied to other confined spaces for air quality monitoring.

KCS540 diffusion exterior view

KCS540 pump suction exterior view

2. Technical parameters

parameter symbol minimum Typical values maximum unit
Storage temperature Tstg -20 - 80 °C
Operating temperature TA -20 60 °C
Operating humidity HA 0 90 % RH
Work pressure PA 0.8 1.2 atm
Supply voltage Vs 9 12 18 V
Maximum operating current Imax 100 120 150 mA
Detection range 200 50000 100% vol can be customized ppm
Measurement accuracy - ± 50ppm or ±3% true value ± 300ppm± 3% true ppm
T90 diffusion - 30 60 second
Repeatability zero <±50 ppm
50% FS - <± 2% of the measured value -
Life Span 3 10 15 year

3. Structural Dimension Drawing

Unit: mm

Ir Ndir Co2 Sensor Module 50000ppm Carbon Dioxide Sensor Module

Diffusion

Ir Ndir Co2 Sensor Module 50000ppm Carbon Dioxide Sensor Module

Pump-suction type

4. Installation instructions

The sensor is mounted with a positioning hole spacing of 44.5mand a mounting hole diameter of 2.8 mm

The wiring socket spacing is 2.54 m m

Note: SW400PV3.01, mounting aperture: 3.2mm

5. Matters that should be paid attention to in maintenance

The sensor should be calibrated regularly, it is recommended that it be no more than 3 months, and calibration is not required on the long-term operation side if automatic calibration is turned on

Do not use the sensor for a long time in an environment with a high density of dust

Please use the sensor within the range of the sensor's power supply

6. Ordering instructions

In order to be able to purchase the specific specifications required, please provide the following information

1) Sensor name

2) Sensor range

3) Sensor measurement accuracy such as SW400, 0-2000pp

8 Order Information

Order information sheet
KCS540 KCS540 CO2 concentration sensor
xxxx The sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm.
2000 Range 200ppm (default).
10000 Range 10000ppm
50000 Range 50000ppm
encode The reaction speed is divided into two types: fast and slow
S Slow (default).
Q fast
encode Baud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering.
Custom Confirm the baud rate before ordering
2400 2400bps baud rate
9600 9600bps baud rate
19200 19200bps baud rate
38400 38400bps baud rate (default)
encode Serial port protocol
Modbus-RTU Standard Modbus-RTU protocol (default).
Modbus-ASCII Standard Modbus-ASCII protocol
Modbus-Self Modbus private protocol
KCS540 -2000 -S -38400 -Modbus-RTU

9. Ordering Instructions

URL: www.kacise.com

Tel: +86-29-17719566736

Email: sales@kacise.com

Address: Tangyan South Road, Xi'an City, Shaanxi Province, China

Appendix

Shorthand Full name
VOL 1% VOL refers to 1% of the volume of a particular gas in air.
PPM 1PPM means that the volume of a specific gas in the air accounts for one millionth.
O2 Oxygen molecules
LCD LCD display
RS485 Asynchronous serial port 485
DC direct current
AC Communication
PVC polyvinyl chloride

Inquiry Cart 0