20m KUS630C Distance Ultrasonic Level Sensor With Temperature Compensation with protection class IP68

Contact Now
Xi'an Kacise Optronics Co.,Ltd.
Visit Website
Province/State:Shaanxi
Country/Region:china
Contact Person:MsEvelyn Wang
Contact Now

20m KUS630C Distance Ultrasonic Level Sensor With Temperature Compensation with protection class IP68

Ask Latest Price
Video Channel
Brand Name :Kacise
Model Number :KUS630C
Place of Origin :China
MOQ :1
Price :Negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :100+
Delivery Time :5-8 work days
Packaging Details :15*15*10cm,0.5kg
Certification :CE
Range :0~20m
Output :4~20mA/NPN/PNP/RS485/0-3V,0-5V
Power supply :3.3-24 V
Working current :≤45mA
Temperature compensation :Yes
Working temperature :-25…70℃(248...343K)
Protection class :IP68
Shell material :PVDF
Measurement accuracy :≤1 %
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

KUS630 Series Ultrasonic Level Meter

1.Features

  • Sophisticated filtering algorithm to exclude spurious measurements
  • A variety of working conditions algorithm selection to ensure measurement accuracy
  • Piezoelectric surge safety protection
  • Automatic sound velocity and temperature compensation
  • Echo curve display, helpful for on-site debugging and fault detection
  • Self-inspection function, rich self-inspection information, convenient for users to repair and debug
  • The range ratio is expanded to prevent the measured value from exceeding the range and causing misjudgment

2.Product description


Non-contact sensing, maintenance free, switch calibration, easy installation, temperature compensation, automatic beamwidth and gain adjustment.

3. Dimensions


Unit in the diagram is mm
20m KUS630C Distance Ultrasonic Level Sensor With Temperature Compensation with protection class IP68

4.Electrical connections and signal definitions

Line order Colour Definition
1 Red Power is positive
2 Black power return ground
3 Yellow Analog output, voltage output, current output switch output
4 Blue RS485 A+ or uart TXD
5 Green RS485 B- or uart RXD

Cable color Line order Describe Remark
red 1 powered by 3.3V-30V wide voltage input
black 2 GND
yellow 3 Switch output Switch terminal, load capacity 1A 60V, supports up to two switch outputs with independent logic, the two terminals are the two contacts of the switch, do not distinguish between positive and negative poles, and can be connected at will.
White 4 Switch output
brown 4 RS485A+
green 5 RS485B-

5.Parameter description

Model:KUS630
Measuring range

0.8m... 20m

Blind spot

0 ... 0.6m(Unstable working area is within 0.6m, it is not recommended to work in this range); the minimum blind area version of 0.3m can be achieved, which needs to be customized.
Supply voltage 3.3 ... 24 V DC , ripple 10 %SS

Working current

≤ 45 mA (fastest measurement speed)

Low-power version, sleep power consumption is less than 0.3mA, sending power consumption is 20mA (less than 2ms), and receiving power consumption is not more than 8mA (less than 150ms)

Output signal

1:Programmable analog output 0-10V.

2:RS485 output.

3:Uart serial output

4:4-20mA output

5:Switch output

Measurement accuracy ≤1 %
Temperature compensation yes

working conditions

Working temperature -25…70℃(248...343K)
Storage temperature -40…85℃(233...358K)

other instructions

Electrical connection 5-core cable (analog output), 6-core cable (switch output);
Protection class IP68
Shell material PVDF

6.Applicable occasions


Manholes, factory water tanks, tanks, municipal engineering, tap water, sewage treatment, water conservancy and hydropower, iron and steel, coal mines, electricity, petrochemicals, urban rivers and lakes, transportation and food processing industries.

7. Ordering Information

KUS Model Output Range Describe
630C Support customization
Custommade
0-10V Analog 0-10V output
0-5V Analog 0-5V output
0-3V Analog 0-3V output
4-20mA Analog 4-20mA output
SW Switch output
Uart Uart serial output MODBUS RTU protocol
RS485 RS485 output MODBUS RTU protocol
XXX mm

XXX mmmeans the maximum measurement distance

(default1000mm)

KUS 550 RS485 10000mm

8.Parameters you need to know


1. The type of medium to be measured (liquid or solid, specific name, clear water, sewage, mud, gasoline, diesel, toluene, sulfur dioxide, etc.) If it is liquid, whether there is steam, mist, foam, waves, stirring, floating objects on the liquid surface ; if solid, whether there is dust.
2. The temperature and pressure of the medium.
3. The corrosiveness of the medium. If it is placed in a jar, it is necessary to know whether the material of the jar has an anti-corrosion lining.
4. The measurement range is a few meters and the blind spot is required.
5. Working environment: such as open pools, pools with covers, horizontal tanks, vertical tanks, spherical tanks, whether the tank is at atmospheric pressure, etc.
6. Working voltage: 24VDC, optional 220VAC can be customized 12VDC/9VDC common power.
7. Output signal: 4~20mA current 485/0-3V, 0-5V voltage output/relay output.
9. Equipment form: whether it needs to have a display; one-piece or split-type.

Inquiry Cart 0