Add to Cart
KUS650 ultrasonic tank level sensor
Application field
• Fire water system.
• City water supply.
• Sewage treatment.
• Long distance heating supply.
• Food industry.
• power chemical or oil industry.
Product features
Power supply: two DC3.6V disposable lithium batteries
Wireless transmit power: <23 dBm
Receiving sensitivity: <-135 dBm
Theoretical bandwidth: 200Kbs
Support wireless transmission of alarm status to server, server address and port can be configured
Adopt precision digital temperature compensation and nonlinear correction technology, wide temperature range and full range precision compensation;
A variety of data type indication (percentage, output current display);
Special wide temperature LCD display (-30℃~80℃);
Provide multiple power supply methods at the same time;
Vertical installation or axial installation, providing a variety of liquid level/level interface and interface materials;
With parameterized LCD and three setting buttons.
According to user needs and site conditions, the collection frequency and collection time interval can be set.
Battery power monitoring, when the power is low, the meter screen flashes and prompts to report to the centralized management platform at the same time.
Water pressure/water level alarm threshold can be set and modified according to actual needs.
Automatic alarm for water pressure/water level alarm threshold.
Technical parameters
Enter | |
Measured variable Liquid |
level, material level
|
Maximum measuremen trange |
1.2-30m (can be customized according to demand)
|
Output | |
Comprehensive accuracy | ±0.15%FS/ 0.15℃ |
Temperature compensation | -10℃~70℃ |
Vibration effects | < ± 0.05%/g, 500Hz in all directions (according to IEC 68-2-64) |
Rated conditions environmental conditions |
|
Ambient temperature | -25~+85℃ |
Storage temperature | -40~+85℃ |
Protection class | IP68 , according to EN 60529 |
Electromagnetic Compatibility | EN 61326/A2 Annex A (2001) |
Display and control | |
Display | SFTN liquid crystal, white backlight, 5-digit display. |
Limit | value Free setting |
Parameter | setting Use 3 buttons |
Unit |
The unit is mm, and the default unit is m.
|
Weight |
about 1.35kg
|
Materials of non-wetted parts | |
Joint | 1NPT, stainless steel, length 20mm (material and joint specifications can be customized according to customer requirements). |
Electrical connection |
Make waterproof connector, air vent cable entry according to EN 175301-803A standard
|
Measurement period | ≤ 100ms |
Selection Tips: For special requirements, please contact our company and indicate it in the order.
parameter settings
1. Send time setting
Opcode: 2121 units (minutes)
In the measurement state, press the "M" key, it will display "-COd-"; press the "M" key to confirm, it will display "00000", the units digit flashes, press the "up and down" key to adjust to "2121"; press the "M" key to confirm, Display "S_TIM", press "M" key, display "00000" (the last set value,), set the value (range 1) by "up" key (data left shift key) and "down" key (data increase key) ~09999), after the adjustment is completed, press the "M" key to confirm and save.
2. Collection time interval setting
Opcode: 2122 units (seconds)
In the measurement state, press the "M" key, it will display "-COd-"; press the "M" key to confirm, it will display "00000", the units digit flashes, press the "up and down" key to adjust to "2122"; press the "M" key to confirm, Display "S_FrE", press "M" key, display "00000" (the last set value,), set the value (range 1~09999) by "up" key and "down" key, press "M" after adjustment is completed key to confirm saving.
3. Data upload method setting
Opcode: 2124
In the measurement state, press the "M" key, it will display "-COd-"; press the "M" key to confirm, it will display "00000", the units digit flashes, press the "up and down" key to adjust to "2124"; press the "M" key to confirm, Display "S.MOdE", press "M" key, display "last set value", use "up" key and "down" key to set, after adjustment is completed, press "M" key to confirm and save.
4. Alarm interval time setting
Opcode: 2125 units (minutes)
In the measurement state, press the "M" key, it will display "-COd-"; press the "M" key to confirm, it will display "00000", the units digit flashes, press the "up and down" key to adjust to "2125"; press the "M" key to confirm, Display "S_ErT", press "M" key, display "00000" (the last set value,), set the value (range 1~09999) by "up" key and "down" key, press "M" after adjustment is completed key to confirm saving.
5. Liquid level/level alarm upper limit setting
Opcode: 2311
In the measurement state, press the "M" key, it will display "-COd-"; press the "M" key to confirm, it will display "00000", the units digit flashes, press the "up and down" key to adjust to "2311"; press the "M" key to confirm, Display "Ad1H", press "M" key to set the upper limit alarm value, set the value by "up" key and "down" key, "Ad1F" alarm upper limit hysteresis value, "Ad1d" alarm upper limit delay, all adjustment Press the "M" key to confirm saving when finished.
6. Liquid level/level alarm lower limit setting
Opcode: 2312
In the measurement state, press the "M" key, it will display "-COd-"; press the "M" key to confirm, it will display "00000", the units digit flashes, press the "up and down" key to adjust to "2312"; press the "M" key to confirm, Displays "Ad2H", press the "M" key to set the upper limit alarm value, use the "Up" and "Down" keys to set the value, "Ad2F" alarm upper limit hysteresis value, "Ad2d" alarm upper limit delay, all adjustments Press the "M" key to confirm saving when finished.
7. Instrument zero calibration
Opcode: 1000
In the measurement state, press the "M" key, it will display "-COd-"; press the "M" key to confirm, it will display "00000", the units digit flashes, press the "up and down" key to adjust to "1000"; press the "M" key to confirm, Display "bd_0" Press the "up and down" keys to select "NO (exit without calibration) or YES (calibration zero)". Press the "M" key to confirm saving and exit.
8. Instrument zero point removal
Opcode: 1511
In the measurement state, press the "M" key, it will display "-COd-"; press the "M" key to confirm, it will display "00000", the units digit flashes, press the "up and down" key to adjust to "1511"; press the "M" key to confirm, Display "CUTO", press the "M" key, it will display "00000" (the last set value), use the "up" and "down" keys to set the value (range 1~29999), press "M" after the adjustment is completed key to confirm saving.
9. Meter offset setting
Opcode: 1510
In the measurement state, press the "M" key, it will display "-COd-"; press the "M" key to confirm, it will display "00000", the units digit flashes, press the "up and down" key to adjust to "1510"; press the "M" key to confirm, Display "OFSET", press "M" key, display "00000" (the last set value,), set the value (range -19999~29999) by "up" key and "down" key, press "M" after adjustment is completed " button to confirm saving.
Storage and transportation
1. The product should be stored at -40℃~+80℃, relative humidity not more than 90%, ventilated, dry, and non-corrosive gas warehouse.
2. The product is packed in the same package with the certificate and instruction manual. Strong collisions are strictly prohibited during transportation.
Note: The contents of the manual are subject to change without notice, please pay attention to keep in touch.
Company information
Xi'an Kacise Optronics Co., Ltd. was founded in 2000, is located in Xi'an, Shaanxi Province, China, is a professional engaged in instrumentation and sensors, R & D, production, sales as one of professional high-tech enterprises, we have our own production workshop and central laboratory. Factory building area is about 3000 square meters, with production of more than 30 employees, 8 engineer, 6 inspectors, 10 saleman, 5 for customer service, is this industry, we are one of the strong technology manufacturers with varieties specification.
When the company set up, we began to focus on the coordination of military supplies production, achieved GB/T19001-2008/ISQ9001:2008, GJB 9001B-2009 certification. When our company is running mature and stable, in 2008, we began to develop our business. Based on the production of military products quality control, we developed a lot of sensor products, such as a pressure sensor / transducer / sensor, level transmitter / ultrasonic level meter / ultrasonic flow meter, inertial navigation products, IMU, gyroscope, accelerometer etc.