Add to Cart
KEC300 Online Conductivity Sensor Water Quality Sensor
Application of electrode type conductivity sensor
Electrode-type conductivity sensors are widely used in production, life and military fields: 1) monitoring the quality of human drinking water;2) Industrial water quality monitoring;3) Battery electrolyte density monitoring;4) Monitoring of water quality in electrolysis oxygen production and hydrogen production devices;5) Marine survey, Marine resources survey, Marine environmental monitoring.
Key technology of electrode type conductivity sensor
1) Elimination of electrode polarization effect
In order to reduce the measurement deviation caused by electrode polarization, methods such as increasing the frequency of the power supply, coating the electrode plate with platinum black, and increasing the plate area are usually adopted.
2) Elimination of capacitance effect
In order to eliminate the capacitance effect and improve the measurement sensitivity, two methods are usually adopted: one is to increase the liquid resistance, which is not easy to achieve;The second is to increase the frequency and reduce the capacitance reactance.But the increase of frequency will be limited to a certain extent, generally high resistance when the use of low frequency, low resistance using high frequency.
3) Design and manufacture of multi-electrode conductance cell
Multi-electrode conductance
cell requires each pair of electrodes to be strictly symmetrical and the distance to other electrodes to be fixed, which puts forward high requirements for the fabrication of electrode base.The electrode base is mostly made of high performance ceramic materials, and the electrode material is mostly made of high performance metal materials. The expansion coefficient of the two materials is quite different, which results in the difficulty of electrode sintering and packaging.The intermediate temperature coefficient of the transition material is usually used for sintering, packaging, but the effect is not very ideal.
Water Quality Sensor Model number | KEC300 |
Water Quality Sensor Measurement parameter | Conductivity, salinity, temperature |
Water Quality Sensor Method of measurement | Four wire graconductivityite electrode method |
Water Quality Sensor Measurement mode | Immersion measurement |
Water Quality Sensor Measuring range | Conductivity: (0 ~ 500mS/cm), salinity: (0-100) ppt Temperature: (0 ~ 60) °C |
Water Quality Sensor Accuracy | ≤ ± 1% |
Water Quality Sensor Repeatability | ≤1% |
Water Quality Sensor Resolution | Conductivity: 0.01 s/cm, salinity: 0.01 PPT |
Water Quality Sensor Response time | ≤20s |
Water Quality Sensor Zero Drift (24h) | ≤ ± 1% F.S. |
Water Quality Sensor Range Drift (24h) | ≤ ± 1% F.S. |
Water Quality Sensor Accuracy of temperature compensation | ≤ ± 1% |
Water Quality Sensor Calibration period | Six months |
Water Quality Sensor Temperature range | (0 ~ 60) °C |
Water Quality Sensor Protection level | IP68 |
Water Quality Sensor MTBF | ≥1440h/Time |
Water Quality Sensor Means of communication | RS485(Modbus RTU), maximum baud rate 115200 bps |
Water Quality Sensor Supply voltage | (12/24) V DC |
Water Quality Sensor Power consumption | < 1W |
Water Quality Sensor Material Quality | Stainless steel, POM |
Water Quality Sensor Weight | 0.5 kg |
Water Quality Sensor Contour dimension | 205 mm × φ40 mm |
Phone +86-17719566736
Email sales@kacise.com
Location Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China