Debug
Because the instrument installation environment is different. Therefore, the ultrasonic level meter must know the basic situation of the measuring environment before working, such as: measuring range, zero, full range and field conditions and so on. Therefore, the instrument must be set before measurement.
Field condition
In any of the following cases, note that:
Liquid/solid with foam
There are strong voltage, strong current and strong electromagnetic interference around, try to avoid high voltage, high current and strong electromagnetic interference
The wind was strong and the sun was blazing
Strong vibration
Volatile liquid and a lot of water vapor on the site
Crystalline liquid
Encounter the above field environment to carefully choose to use, the numerical accuracy of the measurement will decline, the data may be unstable, generally do not recommend the use of ultrasonic level gauge measurement.
Technical Features:
Technical Specifications:
Specs | Value |
Pressure Voltage | 5m, 10m, 15m, 20m, 30m, 40m, 50m, 60m |
Accuracy | 0.5%, 1.0% |
Display | LCD |
Ambient Temperature | Display instrument-20~+60℃ transducer-20~+80℃ |
Medium | liquid and solid |
Analog Output | 4-20mA |
Digital Output | RS485, RS232 (both are optional) |
Power Supply | 24Vdc |
Protection Grade | Display instrument IP65,transducer IP68 |
Probe Type | PVDF, aluminum alloy, ABS, stainless steel 316L, teflon, titanium alloy |
Structure: