Brand Name :KACISE
Model Number :KEF Series
Certification :ISO / CE
Place of Origin :China
MOQ :1pc
Price :Negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time :7 Working days
Packaging Details :Carton / Wooden box
Pressure :1.0Mpa,1.6 Mpa,4.0Mpa,16Mpa (Special)
Diameter :DN25 ~ DN2600
Temperature :-20°C~80°C, 80°C ~130°C, 130°C ~180°C Depending on Lining Material
Power Supply :AC: 220V, 50-60Hz; DC: +24V(Option)
Communication :RS-232; RS-485; HART
Accuracy :0.3% (Option), 0.5%, 1.0% of F.S..
Electrode :SUS316,HC,HB, Ti, Ta, Cu.
Output signal :4~20mA /ADC/0~5V
Installation :Flange, Clamp on, Thread
Protection Class :Integral type: IP65. Remote type: sensor IP68, transducer IP65.
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Sea water Electromagnetic Flow Transmitter Meter Negative Pressure Resistant Electromagnetic Flowmeter Flow Meter

Introduction

KEF series electromagnetic flow meters are intended for fluid measurement in most industries including Electromagnetic flow meters are widely used in industrial sectors such as chemical industry, environmental protection, metallurgy, pharmaceutical, paper making, water supply and removal etc.Besides measuring flow of general conductive liquid electromagnetic flow meter can measure flow of liquid-solid mixed fluid, high-viscosity fluid and salt, strong acid and strong alkali.Electromagnetic flow meter can realize local indication and output electrical current signal of 4-20mA which can be used to record, adjust and control.There are two basic components of electromagnetic flow meter: 1) The Detector, which includes the flow tube, isolating liner and measuring electrodes, and 2) The Converter, which is the electronic device responsilbe for signal processing, flow calculation, display and output signals.The materials of construction of the wetted parts( liner and electrodes) should be appropriate for the specification on the intended type of of service. Revies of the compatibilities consistent with the shipment of each meter.

Features

1. LCD back light display with high clearness. (Option: LED back light display)

2. No intercepting fluid parts, no pressure loss and fluid clogging.

3. No mechanical inertia, quick response and good stability, application in automatic examination, adjustment & controlling.

4. Measuring accuracy not influenced by physical parameters such as style, temperature, viscosity, density and pressure.

6. Supply many styles of flow meters such as inline type and insertion type, etc.

Adopt EEPROM memory to measure operation data, safe and reliable protection of memory.

7. Integral type flow meters and remote type flow meters.

8. Simple structures, firm, no movable parts and long operation life.(Guarantee in 1 years)

Parameters

Items Description
Suitable Diameter DN25~DN2600 (below DN25 non-standard)
Suitable Fluid Liquid with conductive ratio more than 5 μs/cm
Measuring Range 0.5~10m/s (extendable to 15m/s)
Upper Limit of Span 0.5~10m/s. 1~5m/s recommended
Accuracy 0.3% (Option), 0.5%, 1.0% of F.S..
Repeatability Below 0.25%
Display of Converter

Display : Flow rate ( 4-digits), Totalizer (9-digits), Velocity, Alarm status

by LCD ( LED-option)

Scale unit: selectable of L/h, L/m, L/s, m3/h, m3/m, m3/s
Flow direction : selectable by program
3 Digits display below of decimal points.
K-factor: 5 digits.
Data logger for 2-3years.
Programming language: English, Korean(on request)
Mounting: Integral type; Remote Type
Power AC: 220V, 50-60Hz; DC: +24V(Option)
Output Signals

4~20m ADC, load ≤ 750ohm,

0~3kHz, 5V with source and changeable width.

High terminal and effective frequency output

Voltage output:0-5 V DC

Conduit connection M20 * 1.5 Thread
Communication Interface RS-232; RS-485; HART
Operation Pressure 1.0MPa, 1.6MPa, 4.0MPa, 16MPa (Special)
Fluid Temperature -20°C~80°C, 80°C ~130°C, 130°C ~180°C Depending on Lining Material
Ambient Temperature Sensor -40°C ~80°C. transducer -15°C ~50°C
Ambient Humidity ≤ 85%RH (at 20C)
Cable Outlet Size M20×1.5
Power Supply 220VAC±10%, 50-60Hz±1Hz, 24VDC±10%, Battery power (3-5years)
Power Consumption ≤ 8W
Protection Ratings Integral type: IP65. Remote type: sensor IP68, transducer IP65.
Materials Electrode

316L (stainless steel), Hastelloy C, Hastelloy B,

Titanium, Tantalum, etc.

Liner PTFE, Soft rubber, Hard rubber, F46, FS, PUR.
Measuring tube SUS 304
Flange Carbone Steal
Ground ring 316L (stainless steel), HC, Ti, Ta, Cu.
Connection of Flange

National Standard GB9119-88 (DIN2051, BS4504), JIS, ANSI. Screw.

Tri-clamp for sanitary application

Insertion type.

EX-proof protection Exde ib ii BT2
Quality control ISO9001-2008, CE

Model selection

Sea Water Electromagnetic Flow Meter Transmitter Negative Pressure Resistant

Application

Sea Water Electromagnetic Flow Meter Transmitter Negative Pressure Resistant

Sea Water Electromagnetic Flow Meter Transmitter Negative Pressure Resistant

Sea Water Electromagnetic Flow Meter Transmitter Negative Pressure Resistant

Inquiry Cart 0