Add to Cart
Model | KEC601 |
Measuring range | 0~5000μS/cm |
Resolution | 1μS/cm |
Precision | ±1.5%F.S. |
Working Temperature | 0~65℃ |
Working Pressure | <0.6MPa |
Power Supply | 12~24VDC ±10% |
Signal Output | RS-485(Modbus/RTU) |
Wetted Material | ABS/SUS316L(Default)/PVC |
Mounting Method | Immersion mounting, 3/4 NPT thread |
Cable Length | 5 meters, other lengths can be customized |
Temperature Compensation | Auto temperature compensation(Pt1000) |
Calibration | Two-point calibration |
Power Consumption | <0.3W@12V |
Protection Grade | IP68 |
Note: At least 2 cm from the bottom and side walls of the container during installing and testing.
a) Red line - power cord (12 ~ 24V)
b) Black line - ground (GND)
c) Blue line - 485A
d) white line - 485B
e) bare wire - shielded wire
After wiring is completed, it should be carefully checked to avoid incorrect connections before powering up.
Cable specification: Considering that the cable is immersed in water (including sea water) for a long time or exposed to the air, the cable has certain corrosion resistance. The outer diameter of the cable is Φ6 mm and all interfaces are waterproof.