Xi'an Kacise Optronics Co.,Ltd.

Kacise, understanding your automation needs.

Manufacturer from China
Verified Supplier
6 Years
Home / Products / Electromagnetic Flow Meter /

Sanitary Type Electromagnetic Flow Meter Smart Water Flow Meter GXEFM2000

Sanitary Type Electromagnetic Flow Meter Smart Water Flow Meter GXEFM2000

Ask Latest Price
Brand Name :Kacise
Model Number :GXEFM2000
Certification :certificate of explosion-proof, CE
Place of Origin :China (Mainland)
MOQ :1pcs
Price :Negotiable
Payment Terms :L/C, D/A, T/T, D/P, Western Union, MoneyGram
Supply Ability :1000 Pieces per Week
Delivery Time :5-8 work days
Packaging Details :each unit has individual box and all boxes are packed in standard packages or customers requests available
Application range :Electrically conductive fluids
Type :GXEFM2000
Measuring principle :Faraday’s law
Primary measured value :Flow velocity
Secondary measured value :Volume flow
Product :Electromagnetic Flow Meter
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

Kacise sanitary type smart process connection electromagnetic flowmeter insertion electromagnetic flow meter

Description

GXEFM2000 electromagnetic flow meters are intended for fluid measurement in most industries including water, wastewater, food and beverage, pharmaceutical and chemical.

There are two basic components of electromagnetic flow meter:

1) The Detector, which includes the flow tube, isolating liner and measuring electrodes, and

2) The Converter, which is the electronic device responsible for signal processing, flow calculation, display and output signals.

The materials of construction of the wetted parts( liner and electrodes) should be appropriate for the specification on the intended type of service. Revise of the compatibilities consistent with the shipment of each meter.

Technical Data

Measuring system

Measuring principle Faraday’s law
Application range Electrically conductive fluids
Measured Value
Primary measured value Flow velocity
Secondary measured value Volume flow

Design

Features Fully welded maintenance-free sensor
Flange version with full bore flow tube
Standard as well as higher pressure ratings
Large diameter range from DN15~3000 with rugged liners approved for drinking water
Industry specific insertion lengths
Modular construction The measurement system consists of a flow Sensor and a signal converter. It is available as compact and as separate version
Compact version With 511B converter: 110~240Vac Power
With 521B converter: 18~36V DC Power
With W800L/W800W: Battery Power
Remote version

In wall mount version with 211B converter

(110~240Vac or 221B converter 18~36V DC

With W800F converter: Battery Power
Measurement range -12…+12m/s /-40...+40ft/s

Measuring accuracy

Reference conditions Flow conditions similar to EN 29104
Medium: water
Electrical conductivity: ≥300μs/cm
Temperature: +10~+30℃/+50~+80℉

Inlet setion: ≥5DN
Operating pressure: 1Bar/14.5psig
Flow Meter Accuracy Standard: 0.5% of rate
Optional: 0.2% of rate

Operating conditions

Temperature
Process temperature Hard rubber liner: -5~+60℃
Polypropylene liner: -5~+90℃
PTEF liner: -5~+120℃
Ambient temperature Standard (with aluminum converter housing)

-20~+60℃ (Protect electrics against self-heating

with ambient temperature above 55℃

Stroage temperature -20~70℃
Pressure
EN 1092-1 DN2200~3000: PN2.5
DN1200~2000: PN6
DN200~1000: PN10
DN65~150: PN16
DN10~50: PN40
Other pressure on request
ISO insertion length Optional for DN15~600
ASME B16.5 1~24”: 150lb RF
Other pressure on request
JIS DN10~1000/ 2~40”: 10K
Other pressure on request
Pressure drop Negligible

Fluid
Physical condition Conductive liquids
Electrical conductivity ≥5μs/cm
Permissible gas content (volume) ≤5%
Permissible solid content ≤70%

Installation conditions

Installation Take care that flow sensor is always fully filled
For detailed information see chapter “Cautions for installation”
Flow direction Forward and reverse
Arrow on flow sensor indicates positive flow direction
Inlet run ≥5 DN
Outlet run ≥2 DN

Process connection

Flange
EN1092-1 DN25~3000 in PN6~40
ASME 1~120” in 150 lb RF
JIS 25~1000 in 10~20k
Design of gasket surface RF
Other sizes or pressure ratings on request

Ordering information

Model Suffix Code   Description
GXEFM3000 -1200 -Com -4mA -Hart -DC -Pt -Teflon1 -GR -D1400 -Exd IIC T6 Gb  
Diameter -XXXX                   Four Digitals: for example:0010: 10mm: 0015:15mm 0100: 100mm 1000: 1000mm
Transmitter -Com                 Compact type
-Rem                 Remote type
-Bat                 Battery power supply type
-PRO                 process control type
Signal Outpt -N               No output
-4mA               4-20mA
-Pul               1~5KHz pulse
-4Pul               4~20mA / 1~5KHz
Communication -N             No communication
-Hart             HART
-MOD             MODBUS-RTU
-PRO             PROFIBUS
-GPRS             GPRS net
-CDMA             CDMA net
-WHRT             Wireless HART
-Other             special order
Power Supply -AC           85V~250Vac@46~63Hz
nominal 20W
-DC           20~36VDC nominal 20W
-Bat           Battery power supply
-Bat+           Battery +12Vdc dual power supply
Other           special request
Electorde Material -316L         Stainless steel 316L
-HasB         Hastelloy B
-HasC         Hastelloy C276
-Pt         Platinum
-Ta         Tantalum
-Ti         Titanium
-WC         wolfram carbide
Liner material -Rub1       Neoprene(-20-60℃)
-Rub2       Neoprene(-20-90℃)
-Tef1       polytetrafluroethylene(-30-120℃)
-Tef2       polytetrafluroethylene(-20-160℃)
-P       Polyurethane
-FVMQ       FVMQ
-PFA       DFA
-ETFE       Ethylene tetraflurorethylene
Grounding Ring -N     No grounding ring
-GR     Grounding ring
-GE     Grounding Electrode
Wet part Connection attribute -DXX   DXX: D06, D10, D16, D25,D40 D06: DIN PN6:
D10: DIN PIN10D16: DIN PN16; D25: DIN PN25 D40: DIN PN40 etc
-AX   AX: A1, A3, A6 A1: ANSI 150#; A3: ANSI 300# A6: ANSI 600#
-JX   JX: J1, J2, J3 J1: JIS10K;
J2: JIS 20K; J3: JIS 30K
-WF   Wafer connection (available for DN2.5; DN6 flow meter) Body material: stainless steel
-TR   Tri-Clamp for sanitary type (Body material: stainless steel)
Explosive-proof grade -Exd IIC T6 Gb Exd IIC T6 Gb
-N don't need

GXEFM2000 Series Electromagnetic Flow Meter

Sanitary Type Electromagnetic Flow Meter Smart Water Flow Meter GXEFM2000

Sanitary Type Electromagnetic Flow Meter Smart Water Flow Meter GXEFM2000Sanitary Type Electromagnetic Flow Meter Smart Water Flow Meter GXEFM2000Sanitary Type Electromagnetic Flow Meter Smart Water Flow Meter GXEFM2000Sanitary Type Electromagnetic Flow Meter Smart Water Flow Meter GXEFM2000

China Sanitary Type Electromagnetic Flow Meter Smart Water Flow Meter GXEFM2000 for sale

Sanitary Type Electromagnetic Flow Meter Smart Water Flow Meter GXEFM2000

Inquiry Cart 0